Welch Allyn PC-Based SpiroPerfect Spirometer Module, CPWS, and 3 Liter Calibration Syringe
Welch Allyn Part #: SPIRO-S
Turns #: 90-SPIRO-S
List Price: $2,100.00
Tell a Friend

See and compare accurate results from pulmonary function tests in seconds. Clearly evaluate pulmonary obstruction or restriction, increase success rates of patients who are undergoing smoking cessation, show progress, and help pediatric patients comply with test procedures. Includes Sensor, Pressure Tubing, Flow Transducers, Electronic Operator's Manual, Latest CPWS Software CD, 2 Training Posters, and a Quick Reference Card. - Fast, reliable pre-/postbronchodilator FVC, SVC, and MVV testing with automatic interpretation and reversibility analysis
-
Instantly verify quality and variability of test performance and compare previous tests using the trending tool Motivate children with incentive graphic- Reduce risk of cross contamination with single-use disposable transducers
Easily monitor, review, store and print on your computer with Welch Allyn CardioPerfect Workstation Software Interface with EMR or patient management systems for onsite or offsite review of key data
Computer based full diagnostic spirometer
Tests: FVC, SVC, MVV, Pre-Post BD
Sensor Type: Pneumotach
Power Equipment: None, obtained from USB port
Accuracy: Meets or exceed 1994 ATS standard
Reproducibility: Meets or exceed 1994 ATS standard
Volume Range: 0-14 L
Flow Range: +/- 14 L/sec
Software: Windows 2000 and XP compatible
Predictive Norms: Berglund 1963, Crapo 1981, Composite, Dockery 1983,
ECCS / Quanjer 1993, Falaschetti 1995, Gulsvik 2001, Hedenström 1986, Hsu 1979,
Knudson 1976, Koillinen 1998, Kory 1961, Morris 1971, NHANES III, Polgar 1971,
Schoenberg 1978, Solymar 1980, Viljanen 1981, Zapletal 1969. Additional
predictive norms can be added upon customer request.
Interpretation: 1991 ATS Interpretation Standards. Automatic
interpretation can be disabled. Manual Interpretation available. Lung Age
calculation available.
Reports: Multiple formats including: All Plus best Effort FVC, Best MVV,
Best SVC, Best 3 FVC, Measurements, Social security and Trend. Color printing
supported
Incentive graphic: Fireman
Parameters: FVC: FIVC, FIV1, FIV1%, FEV0.5, FEV1, FEV2, FEV3, FEV5, FEV6,
FEV1/FEV6, FEV0.5%, FEV1%, FEV2%, FEV3%, FEV5%, FEV6%, PEF, FEF25, FEF50, FEF75,
FEF0.2-1.2, FEF25-75, FEF75-85, PIF, FIF50, FEF50/FIF50, FET
SVC: ERV, IRV, VT, IC, BF, MV, Tin, Tex, Tin/Tex
Quality Checks: Effort Acceptability and Test Reproducibility checks
Audio and vsual incentive for assistance in coaching
patients
Connectivity: Compatible with CardioPerfect Diagnostic Suit
Export compatible with most electronic medical records programs
Available in multi user network
Telemedicine option for e-mail transfer
Agency Approval: SpiroPerfect meets or exceeds the following
standards: ATS-American Thoracic Society, Standardization of Spirometry, 1994
Update ERS-European Respiratory Society NIOSH-National Institute for
Occupational Safety and Health OSHA-Occupational Safety and Health
Administration SSD-Social Security Disability ECCS-European Community for
Coal & Steel
Minimum Computer Requirements (Recommended): Processor Intel Pentium III (Pentium IV or higher) Hard Drive 2GB (4GB or more) RAM Memory 256MB
(512MB or higher) Monitor Resolution (1024 x 768 true color) Operating
Systems Microsoft® Windows 2000 or XP CD-ROM Required for
installation Printers Color printer recommended. Compatible with inkjet and
laser printers. Laser printers require a minimum of 2MB of memory.
Computer based full diagnostic spirometer
Tests: FVC, SVC, MVV, Pre-Post BD
Sensor Type: Pneumotach
Power Equipment: None, obtained from USB port
Accuracy: Meets or exceed 1994 ATS standard
Reproducibility: Meets or exceed 1994 ATS standard
Volume Range: 0-14 L
Flow Range: +/- 14 L/sec
Software: Windows 2000 and XP compatible
Predictive Norms: Berglund 1963, Crapo 1981, Composite, Dockery 1983,
ECCS / Quanjer 1993, Falaschetti 1995, Gulsvik 2001, Hedenström 1986, Hsu 1979,
Knudson 1976, Koillinen 1998, Kory 1961, Morris 1971, NHANES III, Polgar 1971,
Schoenberg 1978, Solymar 1980, Viljanen 1981, Zapletal 1969. Additional
predictive norms can be added upon customer request.
Interpretation: 1991 ATS Interpretation Standards. Automatic
interpretation can be disabled. Manual Interpretation available. Lung Age
calculation available.
Reports: Multiple formats including: All Plus best Effort FVC, Best MVV,
Best SVC, Best 3 FVC, Measurements, Social security and Trend. Color printing
supported
Incentive graphic: Fireman
Parameters: FVC: FIVC, FIV1, FIV1%, FEV0.5, FEV1, FEV2, FEV3, FEV5, FEV6,
FEV1/FEV6, FEV0.5%, FEV1%, FEV2%, FEV3%, FEV5%, FEV6%, PEF, FEF25, FEF50, FEF75,
FEF0.2-1.2, FEF25-75, FEF75-85, PIF, FIF50, FEF50/FIF50, FET
SVC: ERV, IRV, VT, IC, BF, MV, Tin, Tex, Tin/Tex
Quality Checks: Effort Acceptability and Test Reproducibility checks
Audio and vsual incentive for assistance in coaching
patients
Connectivity: Compatible with CardioPerfect Diagnostic Suit
Export compatible with most electronic medical records programs
Available in multi user network
Telemedicine option for e-mail transfer
Agency Approval: SpiroPerfect meets or exceeds the following
standards: ATS-American Thoracic Society, Standardization of Spirometry, 1994
Update ERS-European Respiratory Society NIOSH-National Institute for
Occupational Safety and Health OSHA-Occupational Safety and Health
Administration SSD-Social Security Disability ECCS-European Community for
Coal & Steel
Minimum Computer Requirements (Recommended): Processor Intel Pentium III (Pentium IV or higher) Hard Drive 2GB (4GB or more) RAM Memory 256MB
(512MB or higher) Monitor Resolution (1024 x 768 true color) Operating
Systems Microsoft® Windows 2000 or XP CD-ROM Required for
installation Printers Color printer recommended. Compatible with inkjet and
laser printers. Laser printers require a minimum of 2MB of memory.
|
 |
|
|
|
|
|